USB-rechargeable CO detectors
These carbon monoxide detectors recharge over USB-C or micro-USB, so you can top them up from a car outlet, power bank or solar setup. They suit vanlifers who want no spare batteries. Compare battery runtime and charging time.
See all 37 carbon monoxide detectors
7 products
| 7 products | Detection capabilities | Alarms | Charging | Core specs | Physical Attributes | Operating Temp Range | Warranty & Certification | |||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Product | Price | Brand | Model | Description | Manufacturer page | User manual | Popular brand | Min. CO detection ppm | Max. CO detection ppm | Resolution ppm | Gases detected | Response time (T90) s | Accuracy | Sensor type | Sensor life years | Built-in pump | Low alarm level ppm | High alarm level ppm | Alarm loudness dB | Adjustable alarm levels | TWA / STEL alarms | Charging time hours | Battery runtime hours | Battery capacity mAh | Charging port | Battery type | Weight lbs | Weight kg | Length in. | Length mm | Width in. | Width mm | Depth/Height in. | Depth/Height mm | IP rating | Operating temp min ℉ | Operating temp min ℃ | Operating temp max ℉ | Operating temp max ℃ | Warranty | Certifications summary | NIST traceable calibration | ATEX / IECEx certified | Class I Div. 1 (UL/CSA) | UL 2034 listed | |
$99.45 | FORENSICS DETECTORS FD | FD-90A-CO | A handheld CO meter covering 0 to 1000 ppm with 1 ppm resolution, ±5% F.S. accuracy and a 30 s response time, shipped with a NIST calibration certificate. It is ATEX certified, offers zero and span calibration and alerts by sound, light and vibration at adjustable levels. Its 1500 mAh battery lasts about 24 hours and recharges over Micro-USB, and its 0 ℉ minimum operating temperature suits colder vans than home alarms. | Yes | 0 | 1,000 | 1 | CO | 30 | ±5% F.S. | Electrochemical | 2.0 | No | 50 | 200 | – | Yes | – | 3.0 | 24 | 1,500 | Micro-USB | Lithium-ion | 0.31 | 0.14 | 4.30 | 109 | 2.30 | 58 | 1.70 | 43 | – | 0 | -18 | 122 | 50 | 1 Year | ATEX | Yes | Yes | – | – | ||||
$79.99 | TOPTES | FD-90A-CO | A rechargeable handheld CO meter with a 0 to 1000 ppm range, a color TFT display with a trend graph, adjustable alarm thresholds and light, sound and vibration alerts. It uses an electrochemical sensor, stores alarm records and offers zero calibration. Priced below most NIST-calibrated meters, it suits buyers who want a meter to check heaters and cabins rather than a fixed alarm. | No | 0 | 1,000 | 1 | CO | 30 | ±5% F.S. | Electrochemical | 2.0 | No | 50 | 200 | – | Yes | – | 3.0 | 24 | 1,500 | Micro-USB | Lithium-ion | 0.31 | 0.14 | 4.30 | 109 | 2.30 | 58 | 1.70 | 43 | – | 0 | -18 | 122 | 50 | 1 Year | ATEX | Yes | Yes | – | – | ||||
$215.45 | FORENSICS DETECTORS FD | FD-4A | A USA NIST calibrated four-gas monitor that reads CO from 0 to 1000 ppm at 1 ppm resolution, plus H2S, O2 and combustible gas, with a 30 s response time and ±5% F.S. accuracy. It runs 20 hours on a 2000 mAh battery, has adjustable alarms and ATEX certification, and weighs 0.51 lbs. It suits buyers who want calibrated, certified multi-gas readings over long days. | Yes | 0 | 1,000 | 1 | CO, H2S, O2 and LEL (combustible gas) | 30 | ±5% F.S. | Electrochemical | 2.0 | No | – | – | 85 | Yes | – | 4.0 | 20 | 2,000 | Micro-USB | Lithium-ion | 0.51 | 0.23 | 5.12 | 130 | 2.64 | 67 | 1.18 | 30 | IP65 | 0 | -18 | 122 | 50 | 1 Year | ATEX | Yes | Yes | – | – | ||||
$265.45 | FORENSICS DETECTORS FD | FD-4S | A four-gas monitor for CO, hydrogen sulfide, oxygen and combustible gas (LEL); it does not measure CO2. It has a color screen with graphs, data logging, NIST calibration, ATEX certification and a 2000 mAh lithium-ion battery that lasts 20 hours and recharges over Micro-USB. Pricier than most CO-only detectors, it suits buyers who also want propane-leak and oxygen warnings, though it needs regular recharging unlike sealed-battery alarms. | Yes | 0 | 999 | 1 | CO, H2S, O2 and LEL (combustible gas) | – | ±5% F.S. | Electrochemical | – | No | 50 | 150 | – | Yes | – | 4.0 | 20 | 2,000 | Micro-USB | Lithium-ion | 0.88 | 0.40 | 5.12 | 130 | 2.64 | 67 | 1.18 | 30 | – | – | – | 122 | 50 | 1 Year | ATEX Ex ib IIC T4 Gb | Yes | Yes | – | – | ||||
$111.99 | Forsensal | FS11301 | A four-gas detector with a built-in pump that reads CO from 0 to 1000 ppm at 1 ppm resolution, plus H2S, O2 and combustible gas, with a 30 s response time and adjustable 50 and 150 ppm alarms. It has a 3000 mAh battery charged over USB-C and comes with a calibration cap and certificate. One of the few pump models listed, it suits sampling hard-to-reach spaces, though its 8 hour runtime is the shortest in the table. | – | No | 0 | 1,000 | 1 | CO, H2S, O2 and LEL (combustible gas) | 30 | – | Electrochemical | – | Yes | 50 | 150 | – | Yes | – | – | 8 | 3,000 | USB-C | Lithium-ion | 0.70 | 0.32 | 2.36 | 60 | 2.60 | 66 | 5.75 | 146 | – | – | – | 131 | 55 | 1 Year | – | – | – | – | – | |||
$199.00 | FORENSICS DETECTORS FD | FD-4X | A four-gas meter that reads CO from 0 to 999 ppm at 1 ppm resolution, plus H2S, O2 and combustible gas, with USA NIST traceable calibration. It has electrochemical sensors, adjustable audio, visual and vibration alarms and a 2000 mAh lithium-ion battery, and it is one of the few meters listed that charges over USB-C. It suits buyers who want calibrated CO readings plus wider gas checks in one handheld. | Yes | 0 | 999 | 1 | CO, H2S, O2 and LEL (combustible gas) | – | ≤ ±5% F.S. | Electrochemical | – | No | – | – | – | Yes | – | 4.0 | – | 2,000 | USB-C | Lithium-ion | 0.55 | 0.25 | 5.10 | 130 | 2.60 | 63 | 1.20 | 33 | IP65 | 0 | -18 | 122 | 50 | 1-year limited warranty | – | Yes | – | – | – | ||||
$65.99 | TOPTES | CT-580 | This handheld CO detector reads 0 to 1000 ppm on a color display and alerts with light, sound and vibration at two adjustable thresholds. It also stores alarm history, offers zero and span calibration, has a built-in flashlight and recharges over USB-C. Its 3-year warranty is longer than most portable meters, and it suits buyers wanting an inexpensive rechargeable meter for checking heaters and campsites. | No | 0 | 1,000 | – | CO | – | – | – | – | – | – | – | – | – | – | – | – | – | USB-C | – | – | – | – | – | – | – | – | – | – | – | – | – | – | 3 Years | – | – | – | – | – | ||||
All products are hidden. Change or clear your filters to see products in this category. | ||||||||||||||||||||||||||||||||||||||||||||||
7 products
Prices from Amazon as of . Product prices and availability are accurate as of the date and time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply to the purchase of the product. As an Amazon Associate I earn from qualifying purchases.
What the columns mean
- Description
- A short description of the product and how it compares to others in its category.
- Manufacturer page
- A link to the manufacturer's product page.
- User manual
- A link to the official user manual for this product, or a page on which the user manual can be found. Usually a PDF file.
- Popular brand
- Products with this designation are popular and well-known in their category.
Detection capabilities
- Gases detected
- Which gases the device measures, such as CO only, or CO plus O2, H2S and LEL (combustible gas). Multi-gas monitors add protection against propane leaks and low oxygen.
- Response time (T90) (s)
- Seconds the sensor takes to reach 90% of the true reading after CO appears. Shorter is better; claims under 1 second usually refer to alarm activation, not sensor response.
- Accuracy
- Stated measurement error, such as ±5% of full scale or ±5 ppm. Note that ±5% of a 1000 ppm full scale is ±50 ppm, which matters at low concentrations.
- Sensor type
- The sensing technology, usually electrochemical for CO (catalytic bead or infrared for combustibles). Electrochemical sensors are the most accurate and specific for CO.
- Sensor life (years)
- How long the CO sensor is expected to work before it must be replaced, or the whole unit retired for sealed disposable detectors.
- Built-in pump
- Whether the unit actively draws air through a pump instead of relying on diffusion, which speeds response and lets you sample through a probe or hose into vents and confined spaces.
Alarms
- Low alarm level (ppm)
- The default CO concentration that triggers the first (low) alarm. Lower levels warn earlier; 35 ppm matches the NIOSH exposure limit.
- High alarm level (ppm)
- The default CO concentration that triggers the high (evacuate) alarm.
- Alarm loudness (dB)
- Sound level of the audible alarm. UL 2034 requires residential CO alarms to reach 85 dB at 10 ft; louder alarms are more likely to wake you.
- Adjustable alarm levels
- Whether you can change the ppm levels at which the alarms trigger.
- TWA / STEL alarms
- Whether the device also alarms on exposure averaged over time: TWA (8-hour time-weighted average) and STEL (15-minute short-term exposure limit), as defined by OSHA and NIOSH.
Charging
- Battery runtime (hours)
- How long the detector runs continuously on a full charge or fresh battery. Matters for overnight monitoring while sleeping in a vehicle.
- Battery capacity (mAh)
- Capacity of the built-in rechargeable battery. Detector makers publish mAh rather than Wh.
- Charging port
- Connector used to recharge, such as USB-C or micro-USB, or none for non-rechargeable units.
Core specs
- Battery type
- The batteries that power the detector: a built-in rechargeable battery, or replaceable batteries such as AA, and their chemistry.
Physical Attributes
- Weight (lbs)
- Item weight in pounds. May be rounded from actual weight.
- Weight (kg)
- Item weight in kilograms. May be rounded from actual weight.
- Length (in.)
- Item length in inches. When comparing products, note that measurements may not be consistently assigned. For example, "length" might just be whichever dimension is largest, regardless of the item's orientation when you use it. A different product might refer to length as a different side. Refer to product manuals and images if you are uncertain.
- Length (mm)
- Item length in millimeters. When comparing products, note that measurements may not be consistently assigned. For example, "length" might just be whichever dimension is largest, regardless of the item's orientation when you use it. A different product might refer to length as a different side. Refer to product manuals and images if you are uncertain.
- IP rating
- Ingress Protection rating under IEC 60529, such as IP67 (dust-tight, survives immersion). Many listings say 'waterproof' without an IP code, which can't be verified.
Operating Temp Range
- Operating temp min (℉)
- Lowest air temperature at which the product is rated to work.
- Operating temp min (℃)
- Lowest air temperature at which the product is rated to work.
- Operating temp max (℉)
- Highest air temperature at which the product is rated to work, relevant in a parked vehicle in summer.
- Operating temp max (℃)
- Highest air temperature at which the product is rated to work.
Warranty & Certification
- Warranty
- Manufacturer warranty information. Note that for some products, the warranty may only cover certain parts, or registration with the manufacturer may be required to activate or extend the warranty. Check warranty details before purchase.
- Certifications summary
- Certifications held by this device.
- NIST traceable calibration
- Whether the unit ships factory-calibrated against a gas standard traceable to the US National Institute of Standards and Technology, usually with a signed calibration certificate. It shows the readings were checked against known CO concentrations.
- ATEX / IECEx certified
- Certified intrinsically safe for explosive atmospheres under the EU ATEX directive or IECEx scheme (for example Ex ia IIC T4). 'Explosion-proof' claims without this certification aren't verified.
- Class I Div. 1 (UL/CSA)
- North American hazardous-location approval (Class I, Division 1, Groups A–D) by UL or CSA, the US/Canada equivalent of ATEX.
- UL 2034 listed
- Listed to UL 2034, the US standard for CO alarms used in homes and RVs, which sets alarm times (e.g. 70 ppm within 60–240 min, 400 ppm within 4–15 min) and an 85 dB siren. Most handheld meters are not listed to it.